2015年9月10日 星期四

SCCM versions


RTM
CU1
CU2
CU3
CU4
CU5
CM07 SP2
4.0.6487.2000





CM12 RTM
5.0.7711.0000
5.0.7711.0200
5.0.7711.301



CM12 SP1
5.0.7804.1000
5.0.7804.1202
5.0.7804.1300
5.0.7804.1400
5.0.7804.1500
5.0.7804.1600
CM12 R2
5.0.7958.1000
5.0.7958.1203
5.0.7958.1303
5.0.7958.1401
5.0.7958.1501
5.0.7958.1604
CM12 SP2/R2 SP1
5.0.8239.1000
5.0.8239.1203




CM16













CU KBs






CM12 RTM

KB2717295
KB2780664



CM12 SP1

KB2817245
KB2854009
KB2882125
KB2922875
KB2978017
CM12 R2

KB2938441
KB2970177
KB2994331
KB3026739
KB3054451
CM12 SP2/R2 SP1

KB3074857




2015年9月6日 星期日

SQL Server 2008 R2 SP2升級到SP3 失敗

[請您參考以下的說明]   
1.       現階段暫時使用其他具有管理員權限的帳號登入後,已經可以正常安裝相關更新。
2.       針對Kerberos Token大小的問題建議可以透過底下方式將大小調整成48000以減少此類問題發生。
步驟:
1)      打開regedit.exe
2)      找到HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa\Kerberos\Parameters , 並在右邊新增一個DWORD值 , 命名為 MaxTokenSize , 並設定其值為48000 (十進位)。

3)      設定完成後重新開機讓該值生效即可

2015年8月13日 星期四

KDC event ID 27 on Windows 2003 DC

You can also perform the following step to solve the problem on windows 2003 DC by adding the registry DWORD “KdcUseREquestedEtypesForTickets” under registry seeting

Hkey_local_Machine\System\CurrentControlSet\Services\KDC

Value Name : KdcUseREquestedEtypesForTickets
Value Type:  DWORD 
Value Data:  1 

2015年8月4日 星期二

Can not found APM Services after install scom agent ?

APM Server 需要檢查下面資訊,才會安裝APM
1. HKCR" Key="CLSID\{BBC3C76B-A765-4BC1-8150-4A20B24325B4

2. NETFRAMEWORK35 OR NET_VERSION_4_0

可以檢查安裝log
msiexec.exe /i C:\TEMP\MOMAgent.msi /qn /l*v C:\TEMP\MOMAgentinstall.log

DisableFirewall

reg add HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\DomainProfile /v EnableFirewall /t REG_DWORD /d 0 /f

reg add HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\StandardProfile /v EnableFirewall /t REG_DWORD /d 0 /f

reg add HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\PrivateProfile /v EnableFirewall /t REG_DWORD /d 0 /f

reg add HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\PublicProfile /v EnableFirewall /t REG_DWORD /d 0 /f

net stop MpsSvc


net start MpsSvc

2015年7月22日 星期三

SCOM - Email notification may not work as expected if a time range is configured only with an exclusion

When using Systems Center Operations Manager , if you configure Notification Recipients  or Subscribers with the option of "Only send notification during the specified times" and you configure it with only an exclude range (like "Except from" with a time range of, say 1:00am to 7:00am for example), email notifications fail altogether.

In the Operations Manager event log you will also see the event below:
Log Name:      Operations Manager
Source:        Health Service Modules
Date:          <date> <time>
Event ID:      31501
Task Category: Notification
Level:         Warning
Keywords:      Classic
User:          N/A
Computer:      <RMS Server Name>
Description:
No primary recipients were specified for the notification or all recipients are unavailable according to the schedules. Notification will not be sent

One or more workflows were affected by this. 
Instance name: Alert Notification Subscription Server
Management group: <Mgmt Group Name>



So to keep this from happening, or to fix it if you’ve already found yourself in this situation, you need to configure the Recipient or Subscriber first with an included time range, then configure your excluded time range.

For example, first configure you include Range like Date  | Range = Always | Time Range = All Day | Weekdays = Week days. then once you have that, configure your Exclude Range like Data Range = Always | Time Range = Excluding 1:00am to 7:00am | Weekdays = Week Days. The screen shot below shows this configuration.

2015年7月15日 星期三

Rebuild the performance counters on Windows Server 2008

1. Open Elevated Command prompt on Server
2. Navigate to C:\Windows\System32
3. Run the command lodctr.exe /S:Backup_Perfcounter.INI    
4. This command is to take a backup of the current performance counters
    on the server
5. After the backup is taken please verify if the file “Backup_perfcounter.INI”
    is available in C:\Windows\System32 on the server
6. Once confirmed, please run the following command
    to rebuild the performance counters      
    lodctr.exe /R:PerfStringBackup.INI    
7. Please reboot the server in order to make sure that
     all the registry changes are implemented.