RTM
|
CU1
|
CU2
|
CU3
|
CU4
|
CU5
|
|
CM07 SP2
|
4.0.6487.2000
|
|||||
CM12 RTM
|
5.0.7711.0000
|
5.0.7711.0200
|
5.0.7711.301
|
|||
CM12 SP1
|
5.0.7804.1000
|
5.0.7804.1202
|
5.0.7804.1300
|
5.0.7804.1400
|
5.0.7804.1500
|
5.0.7804.1600
|
CM12 R2
|
5.0.7958.1000
|
5.0.7958.1203
|
5.0.7958.1303
|
5.0.7958.1401
|
5.0.7958.1501
|
5.0.7958.1604
|
CM12 SP2/R2 SP1
|
5.0.8239.1000
|
5.0.8239.1203
|
||||
CM16
|
||||||
CU KBs
|
||||||
CM12 RTM
|
KB2717295
|
KB2780664
|
||||
CM12 SP1
|
KB2817245
|
KB2854009
|
KB2882125
|
KB2922875
|
KB2978017
|
|
CM12 R2
|
KB2938441
|
KB2970177
|
KB2994331
|
KB3026739
|
KB3054451
|
|
CM12 SP2/R2 SP1
|
KB3074857
|
2015年9月10日 星期四
SCCM versions
2015年9月6日 星期日
SQL Server 2008 R2 SP2升級到SP3 失敗
[請您參考以下的說明]
1.
現階段暫時使用其他具有管理員權限的帳號登入後,已經可以正常安裝相關更新。
2.
針對Kerberos Token大小的問題建議可以透過底下方式將大小調整成48000以減少此類問題發生。
步驟:
1)
打開regedit.exe
2)
找到HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa\Kerberos\Parameters
, 並在右邊新增一個DWORD值 , 命名為 MaxTokenSize , 並設定其值為48000 (十進位)。
3)
設定完成後重新開機讓該值生效即可
2015年8月13日 星期四
KDC event ID 27 on Windows 2003 DC
You can also perform the following step to solve the problem on windows 2003 DC by adding the registry DWORD “KdcUseREquestedEtypesForTickets” under registry seeting Hkey_local_Machine\System\CurrentControlSet\Services\KDC Value Name : KdcUseREquestedEtypesForTickets Value Type: DWORD Value Data: 1
2015年8月4日 星期二
Can not found APM Services after install scom agent ?
APM Server 需要檢查下面資訊,才會安裝APM
1. HKCR"
Key="CLSID\{BBC3C76B-A765-4BC1-8150-4A20B24325B4
2.
NETFRAMEWORK35 OR NET_VERSION_4_0
可以檢查安裝log
msiexec.exe /i C:\TEMP\MOMAgent.msi /qn /l*v
C:\TEMP\MOMAgentinstall.log
DisableFirewall
reg add
HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\DomainProfile /v EnableFirewall
/t REG_DWORD /d 0 /f
reg add
HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\StandardProfile /v
EnableFirewall /t REG_DWORD /d 0 /f
reg add
HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\PrivateProfile /v
EnableFirewall /t REG_DWORD /d 0 /f
reg add
HKLM\SOFTWARE\Policies\Microsoft\WindowsFirewall\PublicProfile /v EnableFirewall
/t REG_DWORD /d 0 /f
net stop MpsSvc
net start MpsSvc
2015年7月22日 星期三
SCOM - Email notification may not work as expected if a time range is configured only with an exclusion
When using Systems Center Operations Manager , if you configure Notification Recipients or Subscribers with the option of "Only send notification during the specified times" and you configure it with only an exclude range (like "Except from" with a time range of, say 1:00am to 7:00am for example), email notifications fail altogether.
In the Operations Manager event log you will also see the event below:
Log Name: Operations Manager
Source: Health Service Modules
Date: <date> <time>
Event ID: 31501
Task Category: Notification
Level: Warning
Keywords: Classic
User: N/A
Computer: <RMS Server Name>
Description:
No primary recipients were specified for the notification or all recipients are unavailable according to the schedules. Notification will not be sent
One or more workflows were affected by this.
Instance name: Alert Notification Subscription Server
Management group: <Mgmt Group Name>
So to keep this from happening, or to fix it if you’ve already found yourself in this situation, you need to configure the Recipient or Subscriber first with an included time range, then configure your excluded time range.
For example, first configure you include Range like Date | Range = Always | Time Range = All Day | Weekdays = Week days. then once you have that, configure your Exclude Range like Data Range = Always | Time Range = Excluding 1:00am to 7:00am | Weekdays = Week Days. The screen shot below shows this configuration.
In the Operations Manager event log you will also see the event below:
Log Name: Operations Manager
Source: Health Service Modules
Date: <date> <time>
Event ID: 31501
Task Category: Notification
Level: Warning
Keywords: Classic
User: N/A
Computer: <RMS Server Name>
Description:
No primary recipients were specified for the notification or all recipients are unavailable according to the schedules. Notification will not be sent
One or more workflows were affected by this.
Instance name: Alert Notification Subscription Server
Management group: <Mgmt Group Name>
So to keep this from happening, or to fix it if you’ve already found yourself in this situation, you need to configure the Recipient or Subscriber first with an included time range, then configure your excluded time range.
For example, first configure you include Range like Date | Range = Always | Time Range = All Day | Weekdays = Week days. then once you have that, configure your Exclude Range like Data Range = Always | Time Range = Excluding 1:00am to 7:00am | Weekdays = Week Days. The screen shot below shows this configuration.
2015年7月15日 星期三
Rebuild the performance counters on Windows Server 2008
1. Open Elevated Command prompt on Server
2. Navigate to C:\Windows\System32
3. Run the command lodctr.exe /S:Backup_Perfcounter.INI
4. This command is to take a backup of the current performance
counters
on the server
on the server
5. After the backup is taken please verify if the file
“Backup_perfcounter.INI”
is available in C:\Windows\System32 on the server
is available in C:\Windows\System32 on the server
6. Once confirmed, please run the following command
to rebuild the performance counters
lodctr.exe /R:PerfStringBackup.INI
to rebuild the performance counters
lodctr.exe /R:PerfStringBackup.INI
7. Please reboot the server in order to make sure that
all the registry changes are implemented.
all the registry changes are implemented.
訂閱: