2014年7月31日 星期四

Unable to install SP1 on 2008 R2 -- [HRESULT = 0x800705b4 - ERROR_TIMEOUT]

1. Open registry by run regedit.exe.
2. Navigate to
HKLM\System\CurrentControlSet\Services\TrustedInstaller right click it and export it for a backup.
3. Set this registry value: BlockTimeIncrement to “2a30” (3 hours timeout)
It should be “384” right now.
4. You may receive error when you set this value, Please right click the “TrustedInstaller” key and set the permission to “Full Control” to users.
5. After that, try to install SP1 again, this time should work.

2014年7月30日 星期三

Update Rollups Released for System Center 2012 SP1 and R2

Update Rollups Released for System Center 2012 SP1 and R2

Update Rollup 3 for System Center 2012 R2
http://support.microsoft.com/kb/2965090

Update Rollup 7 for System Center 2012 Service Pack 1
http://support.microsoft.com/kb/2965089

New Virtual Machine Dashboards for SCOM 2012 R2 UR2

Microsoft has released a new Management Pack (MP) for System Center 2012 R2 that provides quick-glance dashboards for monitoring VMM performance, alerts, CPU, memory, disk, activity, and availability. Provided as an MP means that the downloaded file can be installed and imported into System Center 2012 Operations Manager.  These particular dashboards support System Center 2012 R2 Operations Manager with Update Rollup 2 (UR2) only.

The two dashboards included cover Virtual Machine Manager Host (Hyper-V) and Virtual Machine.
Download them here: System Center 2012 R2 Management Pack for Virtual Machine Manger Host and Virtual Machine Dashboards

2014年7月29日 星期二

SCOM shows Operations Manager failed to start a process

Issue: 
=========
Alert description:
 “The process started at 1:43:02 PM failed to create System.PropertyBagData. Errors found in output:

C:\Program Files\System Center Operations Manager\Agent\Health Service State\Monitoring Host Temporary Files 50\2349\GetDiskPartitionSpace.vbs(136, 5) Microsoft VBScript runtime error:


Analyze:
========
Alert
: Operations Manager failed to start a process

Management Pack Name
: System Center Core Monitoring

Management Pack Version
: 7.0.9538.0

Rule or Monitor:
Rule

Rule or Monitor Name:
Workflow Runtime: Failed to run a process or script

Rule or Monitor Notes:
This rule generates alerts when batch responses fail.

Resolution
:
===============
You can disable those collection rules.
Affected rules:


For Hyper-V 2008 Management Pack:
Free Disk Space Collection Rule


For Hyper-V 2012 Management Pack
Hyper-V 2012 Virtual Machine Hard Drive Percentage of Used Space Collection Rule
Virtual Machine Disk Free Space Collection Rule

The following matrix shows which TS CAL’s and RDS CAL’s can be entered on different versions of the TS and RD Licensing Server:




Terminal / RDS Licensing Server OS Version
CAL Type
Windows Server 2000
Windows Server 2003
Windows Server 2008
Windows Server 2008 R2
Windows Server 2012 or 2012 R2
Windows Server 2000 TS CAL
Yes
Yes
Yes
Yes
No
Windows Server 2003 TS CAL
No
Yes
Yes
Yes
Yes
Windows Server 2008 TS CAL
No
No
Yes
Yes
Yes
Windows Server 2008 R2 RDS CAL
No
No
Yes
Yes
Yes
Windows Server
2012 RDS CAL
No
No
No
No
Yes

2014年7月28日 星期一

"HP Insight NIC Agent" cause Windows Server 2012/2012 R2 Memory Leak

SYMPTOM
若您的環境中有HP ProLiant 主機(任何型號) 並安裝 Windows Server 2012 / 2012 R2 作業系統,主機上的 "HP Insight NIC Agent" 服務會導致系統的WMI服務發生記憶體洩漏問題。
WMI服務記憶體洩漏問題會影響系統的工具運作,這包含Hyper-V 管理員、叢集管理員以及其他任何倚賴WMI的管理工具。
問題發生時伺服器可能包含以下一個或多個症狀
1.           叢集管理員無法連線叢集。Error: "The requested object does not exist"
2.           Hyper-V Manager無法正常運作,無法管理虛擬機器
3.           Wbemtest will report error 0x80010114  “The requested object does not exist”
4.           Winmgmt /verifyrepository -- have error reported in CMD
5.           Msinfo32 failed, collected information is empty
6.           Process explorer.exe cannot start, reporting error “The requested object does not exist”
7.           Tasklist /svc failed reporting “The requested object does not exist”
8.           Svchost.exe and cpqnimgt.exe are the top two memory consumer in the system.
9.           The issue will disappear after server was rebooted. But after a few days, the issue will happen again.

CAUSE
"HP Insight NIC Agent" 服務會週期性的每2分鐘透過WMI對系統查詢 WS2012 /WS2012R2 LBFO/NIC Teaming資訊
l   "select * from MSFT_NetLbfoTeam"
l   "select * from MSFT_NetLbfoTeamNic"
l   "select * from MSFT_NetLbfoTeamMember"

The software may be handling WMI queries in such a way that it does not deregister them from WMI causing the growth. 

WORKAROUND
目前沒有可用的永久修復方法,您可以嘗試以下方法減慢記憶體洩露的速度,
l   通過HP Insight管理代理控制小程式提高Windows SNMP代理刷新週期。 預設刷新週期為2分鐘。 提高刷新週期將大幅減少記憶體洩漏。
l   更新9.50版(和更高版本)的HP Insight NIC Agent程式讓記憶體洩露得到降低(從大約5 Mb/小時到約500 Kb/小時)
l   最後,您可以停用或是解除安裝 "HP Insight NIC Agent" 服務來迴避這個問題