Symptom
=======
Server
Randomly reboots with BugCheck 0xD1
Cause
========
An HP ProLiant server running Windows Server 2012 and configured with one of the HP Smart Array Controllers may blue screen with a Stop 0x000000D1 error, because of a portion of the Smart Array firmware that deals with 64-bit command submissions. HP Windows Server 2012 HPCISSS2.SYS driver Version 62.26.0.64 exposes this error condition because it is the first driver to enable 64-bit command addressing feature support. For information on how to fix this problem, please see the referenced article.
An HP ProLiant server running Windows Server 2012 and configured with one of the HP Smart Array Controllers may blue screen with a Stop 0x000000D1 error, because of a portion of the Smart Array firmware that deals with 64-bit command submissions. HP Windows Server 2012 HPCISSS2.SYS driver Version 62.26.0.64 exposes this error condition because it is the first driver to enable 64-bit command addressing feature support. For information on how to fix this problem, please see the referenced article.
Current
HpCISSs2.sys version: 62.26.0.64 Pass 13 (x64-W2012)
Required
downgraded HpCISSs2.sys version: 62.24.2.64
Solution
===========
This link explains the issue: http://support.microsoft.com/kb/2863960
===========
This link explains the issue: http://support.microsoft.com/kb/2863960
Please downgrade HPCISSS2 driver from 62.26.0.64 to 62.24.2.64.
This is targeted to be resolved in a future version of the HPCISSS2.SYS driver.
To avoid the blue screen, downgrade the HPCISSS2.SYS to Version 62.24.2.64.
Version 62.24.2.64 of the HPCISSS2.SYS is
available as follows:
http://www.hp.com/swpublishing/MTX-9175345236064183975c0c817f
http://www.hp.com/swpublishing/MTX-9175345236064183975c0c817f
More
Information
沒有留言:
張貼留言